Deutz — 05.01.01 Speed Control System Safety Precautions (Woodward UG 8 D/L Hydraulic Governor)

© 0585 Speed Control System Safety Precautions (Woodward UG 8 D/L Hydraulic Governor) Job Card No.: 05.01.01 Engine: S/BVM 628 Filing No.: 0178-27-10 1985 If work is to be carried out on a speed governor, engine control unit, governing linkage and injection pump, strictly observe the following safety precautions. Prior to Work Stop engine. Close shut-off valve (2) on air receivers (1). Bleed air supply line (3) to starting air master valve (4). Following Work Open shut-off valves (2) on air receivers (1).

Provided the linkage is properly adjusted, the engine can also be stopped (to prevent racing) by turning the lever on governor (terminal) shaft (6) toward the © 25 575 1 engine's driving end, using wrench (5) of SW 27 (mm a/fl). With UG 8 D governor engine may also be stopped by setting "Load Limit" button to zero. © 25 281 1 © 50 041 1 © 25 575 1 © 25 575 1 © 50 041 1 © 50 041 1 © 25 281 1 © 25 281 1