Deutz — 05.00.01 Speed Control System Safety Precautions Regulateurs Europa Ltd. Hydraulic Governor

© 0585 Speed Control System Safety Precautions Regulateurs Europa Ltd. Hydraulic Governor Job Card No.: 05.00.01 Engine: S/BVM 628 Filing No.: 0178-27-10 1987 If work is to be carried out on a speed governor, engine control unit, governing linkage and injection pump, strictly observe the following safety precautions. Prior to Work Stop engine. Close shut-off valve (2) on air receivers (1). Bleed air supply line (3) to starting air master valve (4). Following Work Open shut-off valves (2) on air receivers (1). Should the engine tend to race on starting, press stopping button (5).

Provided the linkage is properly adjusted, the engine can also be stopped by turning the lever on governor © 25 575 1 (terminal) shaft (6) toward the engine's driving end, using wrench (5) of SW 27 (mm a/fl). © 50 046 1 © 25 281 1 © 50 047 1 © 25 575 1 © 25 575 1 © 50 046 1 © 50 046 1 © 25 281 1 © 25 281 1 © 50 047 1 © 50 047 1