Deutz — 05.03.11 Woodward UG 8 D/L Hydraulic Governor Servicing (Oil Change)

© 0585 Woodward UG 8 D/L Hydraulic Governor Servicing (Oil Change) Job Card No.: 05.03.11 Engine: S/BVM 628 Filing No.: 0178-27-10 1988 Servicing Tools: (Oil Change) - Standard tools Contaminated oil will lead to governor trouble. Job Card: Be sure to use fresh oil only as specified by - 05.03.12 governor manufacturers which will guarantee proper, satisfactory operation and long ser- vice life of governor. The old oil is drained in hot condition. Before filling in new oil check that the containers used are clean. If necessary, wash them in clean diesel fuel. During the oil change the governor may be removed or in position on engine. To change the oil proceed according to the Woodward manual.

Observe safety precautions (job card 05.00.01) when restarting the engine and during the test run. Adjust needle valve (job card 05.03.12) if governor does not function properly..