© 0593 Regulateurs Europa Ltd. Hydraulic Governor Linkage Setting Job Card No.: 05.04.14 Page 3 of 11 Engine: S/BV 6/8 M 628 Filing No.: 0178-29-10 1806 When Removing Governor Unscrew fastening bolt (*) - Fig. 3), remove link C3 and take down governor. Mid- pos. © 24 925 1 Fig. 3 Refitting the Linkage For following operations, see also Fig. 1. Checking Linkage Settings 1. Before refitting links C1and C3, check pertaining distance dimensions. They must be as follows: Link C1 = 310 mm, see Fig. 3 Link C3 = 86 mm, see Fig. 3 Mid- pos. © 24 925 1 © 24 925 1