Deutz — 05.04.14 Regulateurs Europa Ltd. Hydraulic Governor Linkage Setting, S/BV 6/8 M 628

© 0583 Job Card No.: 05.04.14 Page 10 of11 Regulateurs Europa Ltd. Hydraulic Governor Linkage Setting Engine: S/BV 6/8 M 628 Filing No.: 0178-29-10 1806 12. Set stop screw A13 so that load indicator on injection pump points to graduation (14) - Fig. 15. © 24 938 1 Fig. 15 13. Check that linkage abuts at stop screw (*) - Fig. 16 - when pushed to maximum load (point A13). Upon completion of the setting, lead-seal the engine output (**). © 24 939 1 Fig. 16 14. After the engine has been put back to service and final load setting has been made, check that the governor scale gives the follo- wing readings:

No load = graduation 2 Full load = graduation 8 Failing this, adjust linkage (points C8 or C10 under 11.). © 24 938 1 © 24 938 1 © 24 939 1 © 24 939 1