Specification Data Section: 3.3 Page: 3-1-07 Engine: S/BV 6/8/9 M 628 3.3.3 Setting data for monitoring equipment Minimum equipment marine propulsion auxiliary stationary engines marine engines Data in “bar” Pressure monitor engine speed (referring to dropping pressure) ≤ 600/min > 600/min lube oil pressure: initial alarm – – 2,0 – main alarm (engine stop) 1,0 2,0 1,8 2,0 Temperature monitor Data in „°C“ circ. cool. water temp circuit I 85 85 85 charge air temp., max. 65 65 65 Other monitors rated speed overspeed protection 110 %n 110 %n 110 %n 1 1 1 Further setting data may be obtained from the gauge point list which is included in the engine documentation.
engine speed ≤ 600/min > 600/min – – 1,0 2,0 Data in “bar” 2,0 1,8 85 65 Data in „°C“ 85 65 110 %n 1 rated speed 110 %n 1