Deutz — 05.04.14 Regulateurs Europa Ltd. Hydraulic Governor Linkage Setting, S/BV 9 M 628

© 0583 Regulateurs Europa Ltd. Hydraulic Governor Linkage Setting Job Card No.: 05.04.14 Page 11 of 11 Engine: S/BV 9 M 628 Filing No.: 0178-29-10 1807 15. Setting the starting fuel limit: While the engine is running at 11 bar b.m.e.p., pressurize air cylinder of fuel limit and adjust refitted lever so that there is contact at point (**) - Fig. 17 - . Tighten screw (*), depressurize air cylinder. After finally completing the settings, refit the covers at points A22, A25, A23 and A26 - Fig. 1 -, together with new gaskets, if necessary. Remount the linkage covers. © 24 940 1 Fig. 17 © 24 940 1 © 24 940 1