© 1283 Job Card No.: 05.04.14 Page 10 of 12 Barber-Colman plus 8 Electronic Governor Linkage Setting Engine: S/BV 9 M 628 Filing No.: 0178-29-10 1811 11. Adjust linkage at points C8 (*) or C10 (**) - Fig. 17 - so as to obtain the settings scheduled in Graduation table at right. Then tighten all locknuts. Actuator Injection Pump 9° from Stop 0 Stop limit position - 2,5 to - 5 34° from Stop approx. 14 Section A - B © 24 937 1 Fig. 16 Typical setting Governor Injection Pump © 24 951 1 Graduation Actuator Injection Pump 9° from Stop 0 Stop limit position - 2,5 to - 5 34° from Stop approx. 14 Section A - B © 24 937 1 © 24 937 1 Governor Injection Pump © 24 951 1 © 24 951 1