© 1199 Turbocharger Servicing Job Card No.: 06.12.01 Engine: S/BVM 628 Filing No.: 0178-43-10 1937 Servicing Detergent: - Clean fresh water Cleaning of the charger at full load. - VTR 201/214, 0,3 ltrs. - VTR 251/254, 0,5 ltrs. To prevent a loss in power due to contamina- tion of the charger unit, clean charger during operation - at full load or at least 60% load - by injecting clean water into the charger. In this process the water does not serve as a solvent. The dirt build-up is removed by the striking droplets. Job: G Loosen turning handle (3) and remove cover (2) with gasket. G Fill housing (4) with the respective amount of water. G Refit gasket with cover and fasten turning handle (3).
G Press-in knob (5). Make sure that the whole amount of water is injected from the housing within 4 to 10 seconds. Air A success of the cleaning action is indicated either Water by a raise of the charge air pressure or by a drop of the exhaust gas temperatures. Wait for min. 10 minutes before repeating the cleaning procedure. G Wait for at least 5 minutes before running engine under full load. Ventilation © 51 313 0 Air Water Ventilation © 51 313 0 © 51 313 0