Deutz — 07.02.05 Constant Delivery Setting

© 1284 Constant Delivery Setting Job Card No.: 07.02.05 Engine: S/BVM 628 Filing No.: 0178-17-10 1960 Maintenance Job Cards: - 05.00.01 Prior to installing a new pump element, it is necessa- - 11.01.05 ry to set the pump element for constant delivery. Tools: - Standard tools Job Check thermocouples as per Job Card 11.01.05. Slacken locknut (13) - Fig. 1. By means of guide (16) - eccentric - adjust lug (3) so that it is positioned at an angle of 90° relative to the control rod. Tighten locknut. When subsequently checking at low idling, the cylin- der related to the renewed element must fire reliably.

This can be ascertained from the exhaust tempera- ture, which should be about the same as that of the other cylinders. Refer also to the acceptance docu- ments. If necessary, the injection quantity and thus the exhaust temperature must be corrected by turning the guide (16). Turn clockwise to reduce quantity Turn anti-clockwise to increase quantity We recommend having the injection pump checked at the next opportunity by a DEUTZ Service Station. © 25 554 1 Fig. 1 © 25 554 1 © 25 554 1