Deutz — 11.01.02 Pressure Switch (Oil, Water, Air) Inspection/Testing/Servicing

© 1283 Pressure Switch (Oil, Water, Air) Inspection/Testing/Servicing Job Card No.: 11.01.02 Engine: S/BVM 628 Filing No.: 0178-48-10 1190 Tools: - Standard tools, - testing gauge, - setting mandrel - Testing hose with standard test flange (Section 1.8) - Commercial test pump Inspection / Testing Inspect and test the switch for proper functioning Pressure switches are available for the follo- wing media: lube oil, fuel, raw water, fresh water, injector coolant, control (pilot) air, star- ting and charge air pressure. Settings are indicated on the switch in bar (kp/ cm2). Check whether setting is to fix minimum © 51 355 0 (dropping) or maximum (rising) limits.

(Termi- nal 212 / 212 always for rising function). Job: Clean housing (1) externally. Check that all bolts/ screws and stuffing box screwing (2) are tight. Be sure no lead can chafe. Close cock (3). Unscrew cap nut (4) and connect testing hose. Connect test gauge to hose flange. Subject switch to a higher working pressure by a commercial test pump. Check that switch trips as the pressure falls or rises (depending on setting and application). The test gauge indicates the prevailing working pressure. Compare actual tripping point (e.g. for release of an alarm) to the preset tripping point (see Section 3.3).

Servicing Setting the trip point For altering the setting (trip point), loosen fixing screw (6) and turn adjusting screw; clockwise raises pressure, counterclockwise reduces pressure. As the desired setting is obtained, lock adjusting screw (7) by fixing screw (6). Adjusting screws have RH thread. The integral microswitches are of the single- pole quick-action type and must never be removed. Nor must the sensor retaining screws be slackened or removed. Be sure to replace defective pressure switches as a complete unit. © 51 356 0 © 51 355 0 © 51 355 0 © 51 356 0 © 51 356 0