© 1283 Flow Switch (Fuel Injection) Testing Job Card No.: 11.01.03 Engine: S/BVM 628 Filing No.: 0178-48-10 1191 Testing Tools: - Srandard tools Check that flow switch for shielded injection lines - Tundish works properly. The switch can work properly only when the fuel back leakage line is installed with consi- stent gravity feed to the collector tank. Alarm by the flow switch in service may be caused by a broken line or a leaky connection. Job Clean switch (2) externally and make sure that con- nections are tight. With the engine in service, unscrew union (1) and take out blanking cone. Put tundish on pipe connection and fill in diesel fuel.
The switch (2) should now release an alarm as long as the diesel flow continues. If no alarm is released, eliminate the cause of the trouble or replace the switch. Injection pump Check that the electric lead is properly instal- led so as not to “chafe”. © 51 357 0 Injection pump © 51 357 0 © 51 357 0