Deutz — 11.08.01 Service-warning Switch Checking

© 1283 Service-warning Switch Checking Job Card No.: 11.08.01 Engine: S/BVM 628 Filing No.: 0178-48-10 1859 Checking Tools: - Standard tools Inspect and test function of the service warning - Testing pressure gauge switch on lube oil filter with engine stopped. - Testing hose (Section 1.8) - Standard testing pump In the case of excessive contamination of the Job Card: lube oil paper microfilter, the service warning - 08.00.01 switch causes a differential pressure warning to be given. Job Observe instructions given in Job Card No. 08.00.01 Clean exterior of housing. Check fastening screws for tight seating. Remedy any leaks. Ensure that the connection cables do not chafe.

By means of hand wheel or 8 mm open-end spanner, turn cock (1) to test position II. Remove screw plug (2). Connect up testing hose, pressure gauge and testing pump. Actuate pump and read off pressure at gauge. At a pressure of 1± 0.2 bar, the differential pressure warning must be given. Defective service warning switches must be renewed complete. Remove testing hose, refit screw plug (2) complete with seal ring. Finally, turn cock (1) back to operating position I. © 25 136 1 © 25 136 1 © 25 136 1