Deutz — 4.4 Stoppage / Layoff of Engine Running on Distillate Fuel

© 0185 Operating the Engine Section: 4 Page: 4-3-01 Engine: S/BVM 628 4.4 Stoppage / Layoff of Engine Running on Distillate Fuel A Short period (Engine remains readily available) B Prolonged Period C Period exceeding 3 months Item Job A B C 1 To prevent heat accumulation, let engine idle for 10 minutes or so before shutting down from prolonged full-load service. Where separate oil and coolant pumps are provided, keep them going for 10 minutes following engine shutdown.

G G G 2 Stop engine G G G 3 Close shut-off valve of air receiver G G 4 Close shut-off valves of fuel service tank G G 5 Close shut-off valves before and after water colle G G 6 When frost is imminent, switch on water preheater, unless an anti-freeze has been added, or drain all water from engine and attachments (see Job Card 09.00.01) G 7 Drain all water from engine and attachments (see Job Card 09.00.01) G 8 Drain all lubricating oil from engine and attachments (except speed governor) G 9 Preserve engine (section 6.5) G 10 While the engine is out of service, switch on standby lube oil pump once a week, open indicator valves and turn engine over.