SAFETY PRECAUTIONS FOR MAINTENANCE WARNING: Failure to follow these safety precautions may lead to a serious accident. Cleaning inside or cooling system: see “INITIAL 250 HOURS SERVICE” on page 182. Checking cooling water level, hydraulic oil level : see “CHECK BEFORE STARTING” on page 197. Checking lubricating oil level, adding oil: see “MAINTE- NANCE SCHEDULE CHART” on page 178.” Changing oil, replacing filters: see “MAINTENANCE SCHEDULE CHART” on page 178.” PRECAUTIONS FOR REMOVAL AND INSTALLATION OPERA- TIONS When removing or installing attachments, obey the following pre- cautions and take care to ensure safety during the operation.
G Carry out the removal and installation operations on a flat, firm ground surface. G When the operation is carried out by two or more workers, determine signals and follow these during the operation. G When carrying heavy objects (more than 25 kg), use a crane. G When removing heavy parts, always support the part before removing it. G When lifting such heavy parts with a crane, always pay care- ful attention to the position of the center of gravity. G It is dangerous to carry out operations with the load kept sus- pended. Always set the load on a stand, and check that it is safe. G When removing or installing attachments, make sure that they are in a stable condition and will not fall over.
G Never go under a load suspended from a crane. Always stand in a position that is safe even if the load should fall. For details of removal and installation operations, please contact your Komatsu distributor. 43