Rear Axle 35 Rockwell Drive Axle Lubricant Capacities, Single Axles Axle Type Axle Model Capacity * pints (liters) Axle Type Axle Model Capacity * pints (liters) RS–13–120 16 (7.6) RS–19–220 31 (14.7) RS–15–120 16 (7.6) RS–21–145 32 (15.1) Single RS–15–210 16 (7.6) RS–21–160 39.5 (18.7) RS–17–140 31 (14.7) RS–21–230 39 (18.5) Single RS–17–145 33.6 (15.9) RS–23–160 42 (19.9) RS–17–220 31 (14.7) RS–23–240 45 (21.3) * Quantities listed are approximate and include 1 pint (0.5 liter) for each wheel end and with the drive pinion at 3 degrees.
Single drive axles equipped with traction equalizers may require a "friction modifier" to correct a slip-stick condition, as described in the vehicle driver’s manual. Rockwell’s experience shows that the following additives perform adequately: Add Elco No. 2 Friction Modifier (1 ounce [30 ml] of additive for each 1 pint [0.5 liter] of lube capacity) or Lubrizol No. 797 or 762 (1 ounce [30 mL] of additive for each 1 pint [0.5 liter] of lube capacity). Table 2, Rockwell Drive Axle Lubricant Capacities, Single Axles RS–19–145 34.4 (16.3) able for determining the useful life of their product under actual service conditions.
The final schedule that is recommended may, for economic reasons, be correlated with lubricant changes that are governed by climatic conditions and magnetic plug mainte- nance. Change lubricant type and viscosity as cli- matic temperatures demand, regardless of vehicle mileage or established change schedule. Rockwell Drive Axle Lubricant Capacities, Tandem Axles Axle Model Capacity * pints (liters) RT–34–135 Forward 29.8 (14.1) Rear 34 (16.1) RT–40–145 Forward 30.4 (14.4) Rear 34.4 (16.3) The normal operating temperature of compounded lubricants during the summer season is about 160° to 220°F (71° to 104°C).
The chemicals and addi- tives that give these lubricants increased load- carrying capacity, oxidize faster at temperatures above 220°F (104°C), contributing to more rapid lu- bricant deterioration. For this reason, lubricants of this type, that operate continuously at high tempera- tures, must be changed more frequently. * Quantities listed are approximate and include 1 pint (0.5 liter) for each wheel end and with the drive pinion at 3 degrees. Table 3, Rockwell Drive Axle Lubricant Capacities, Tandem Axles 35–02 Axle Breather Checking The axle housing breather ( Fig. 1 ) must remain clean. Whenever the axle lubricant level is checked, check that the axle breather is open.
Check more often under poor operating conditions. If the breather is plugged, clean or replace it as needed. CAUTION Failure to change the axle lubricant at more fre- quent intervals, when adverse operating condi- tions require, could result in axle damage. 35–03 Axle Lubricant Changing and Magnetic Plug Cleaning Axle Draining and Flushing 1. Remove the plug at the bottom of the housing and drain the lubricant while the unit is warm. Allow enough time for all the old lubricant to drain completely. A regular schedule for changing the axle lubricant in a particular vehicle and operation can be accurately determined by analyzing oil samples taken from the axle at specified intervals or mileages.
Lubricant sup- pliers frequently make their laboratory facilities avail- Business Class Trucks Maintenance Manual, January 1998 35/2