Brakes 42 3.3 If the free-stroke is incorrect, remove the pressure-relief capscrew, gasket, pawl spring, and pawl ( Fig. 6 , Ref. 5) from the slack adjuster housing. If equipped with a pull-pawl assembly ( Fig. 8 ), carefully in- sert a screwdriver and raise the relief cap about 1/8 inch (3.2 mm). A A B f420181a 07/05/95 A. Shorten stroke. B. Lengthen stroke. Fig. 9, Brake Stroke Adjusting 4. Check for correct brake chamber stroke. 4.1 With the brakes fully released, measure the distance from the bottom of the brake chamber to the center of the large clevis pin. See Fig. 7 , Ref. A. f420693a 09/27/94 A. Insert screwdriver here. 4.2 Build air pressure to 100 psi (690 kPa).
Shut down the engine. Fully apply the brakes, then measure the distance from the bottom of the brake chamber to the center of the large clevis pin. See Fig. 7 , Ref. B. The difference between the mea- surements is the brake chamber stroke. Fig. 8, Pull-Pawl Assembly (sectional view) CAUTION Before turning the adjusting nut, remove the pressure-relief capscrew, gasket, pawl spring, and pawl. If equipped with a pull-pawl assembly, raise the relief cap as instructed. Failure to do so could strip the teeth on the pawl. 4.3 The brake chamber stroke must be less than the measurements shown in Table 4 .
If the brake chamber stroke is incorrect, remove the pressure-relief cap- screw, gasket, pawl spring, and pawl ( Fig. 6 , Ref. 5) from the slack adjuster housing. If equipped with a pull-pawl as- sembly ( Fig. 8 ), carefully insert a screw- driver and raise the relief cap about 1/8 inch (3.2 mm). 3.4 Turn the adjusting nut one-eighth turn, as shown in Fig. 9 . Measure the stroke again, and adjust until correct. CAUTION Do not make the adjusted chamber stroke too short. The free-stroke must not be less than the measurements given previously. If the chamber stroke is too short, the linings can drag, which could damage the brake.
Maximum Allowable Brake Chamber Stroke, with Meritor Automatic Slack Adjusters 3.5 If removed, install the pawl, pawl spring, gasket, and pressure-relief capscrew. Tighten the capscrew 15 to 20 lbf·ft (20 to 27 N·m). Or, remove the screwdriver from the pull-pawl assembly (if equipped). Chamber Size Effective Area: square inches Maximum Allowable Stroke: * inches (mm) (B minus A) 12 Less than 1-3/8 (35) 16 Less than 1-3/4 (44) 20 Less than 1-3/4 (44) Business Class Trucks Maintenance Manual, October 1998 42/9