Brakes 42 Remove the old boot from the link. see Group 42 of the Business Class ® Trucks Service Manual. 2.3 Install a new boot on the link, heavy sec- tion down. Be careful not to damage the boot. 5. If there are no problems with the foundation brakes, manually adjust the slack adjuster as follows: 2.4 Seat the boot so that the bottom of the boot is in the boot insert, and the top is in the groove of the link. 5.1 Turn the adjusting hexnut three-quarters of a turn counterclockwise. See Fig. 10 . 2.5 Rotate the adjusting hexnut clockwise until the 1/4-inch hole in the clevis lines up with the hole in the link. B A Install the 1/4-inch clevis pin and the cot- ter pin.

2.6 Tap the clevis upward or downward until the large hole in the slack adjuster lines up with one in the clevis. Install the 1/2-inch clevis and the cotter pin. WARNING Make sure both clevis pins are installed. Failure to do so will cause the slack adjuster to work incor- rectly, which could lead to loss of braking control. This could result in an accident causing personal injury or property damage. 09/27/94 f420434b 3. Check for correct chamber stroke. A. With the brakes released, measure this distance. B. With the brakes applied, measure this distance.

3.1 With the brakes fully released, use a ruler to measure the distance from the bottom of the brake chamber to the center of the large clevis pin. See Fig. 11 , Ref. A. Fig. 11, Brake Stroke Check, Gunite Automatic Slack Adjuster Maximum Allowable Brake Chamber Stroke, with Gunite Automatic Slack Adjusters 3.2 Build air pressure to at least 85 psi (585 kPa). Apply the brakes, then measure the distance from the bottom of the brake chamber to the center of the large clevis pin. See Fig. 11 , Ref. B. The difference between the measurements is the brake chamber stroke.

Chamber Size Maximum Allowable Stroke 12 Less than 1-3/8 inches (35 mm) 16 Less than 1-3/4 inches (44 mm) 20 24 Compare this measurement with those shown in Table 5 . 24 (long stroke) Less than 2 inches (51 mm) 30 4. If the brake chamber stroke exceeds the mea- surements shown in Table 5 , check the founda- tion brakes for problems such as worn cams, bushings, pins and rollers, or broken springs. Repair or replace as needed. For instructions, Table 5, Maximum Allowable Brake Chamber Stroke, with Gunite Automatic Slack Adjusters 5.2 Keeping the wrench on the adjusting hex- nut, have someone apply the brakes sev- eral times while you watch the hexnut.

It Business Class Trucks Maintenance Manual, October 1998 42/13