Heater and Air Conditioner 83 83–01 Air Conditioner Checking, R–12 and R–134a Refrigerant Systems 4. Check air flow from the vents. If there is not enough air flow, check the air intake vent for blockage, and the blower motor for proper opera- tion. If the air flow is not cold enough, see Group 83 of the Business Class ® Trucks Service Manual. Preliminary Checks 5. Carefully feel the system lines. The compressor discharge line should feel hot. 1. Apply the parking brakes and chock the tires. 2. Make sure the refrigerant compressor drive belt is not damaged, and is correctly tensioned. Also check the tightness of the compressor mounting fasteners.
For instructions and torque values, see Group 01 of the Business Class ® Trucks Service Manual. The condenser inlet line should be notice- ably warmer than the outlet line. The line from the condenser should feel warm. The inlet and outlet lines of the receiver- drier should be about the same tempera- ture. 3. Using a feeler gauge, check for correct clutch clearance. For instructions, see Group 83 in the Business Class ® Trucks Service Manual. The line from the receiver-drier to the evaporator should feel warm. 4. Inspect the compressor clutch coil wire. Check the connector for damage or looseness. Replace the wire if it is damaged.
The line from the evaporator to the com- pressor should feel cold. NOTE: Oily spots on the lines or at the fittings could indicate a system leak. 5. Check for broken, burst, or cut hoses. Also check for loose fittings on all parts. WARNING Refrigerant Checking 1. If equipped with a moisture indicator sight glass, check the color of the moisture indicator. See Fig. 1 , Ref. 1. Wear eye protection when using compressed air or high-pressure water to clean parts, as perma- nent harm to eyes could result from flying debris. 6. Check for a build-up of road debris on the con- denser fins.
Using a whiskbroom and air pres- sure, or a spray of soapy water, carefully clean off the condenser; be careful not to bend the fins. If the indicator is a deep cobalt blue, the refriger- ant charge is dry. If the indicator is not blue, the system is contami- nated with water; recover the refrigerant, replace the receiver-drier, evacuate the system, and add a full refrigerant charge. Cooling Checking 1. Start the engine, and set engine speed at 1500 rpm. Close the doors and windows. 2. On R–12 refrigerant systems only, check the receiver-drier sight glass. See Fig. 1 , Ref. 2. IMPORTANT:
When outside temperature and humidity are high, it will take longer to cool the cab, especially if fresh-air vents are left open. The presence or absence of bubbles tells whether or not the system has enough refriger- ant. Bubbles normally appear when the system is started, then disappear after a few seconds. Only an occasional bubble should be seen during nor- mal operation. If bubbles continue all of the time the system is running, the system is merely low on (not completely out of) refrigerant. 2. Turn on the air conditioner; set the controls at maximum cooling and blower speed. 3. Allow the system to run for at least 10 minutes (longer on hot and humid days).
Business Class Trucks Maintenance Manual, January 1998 83/1