Komatsu — CLSS

STRUCTURE AND FUNCTION, MAINTENANCE STANDARD CLSS 4) LS bypass plug PP: Pump circuit PLS: LS circuit TS: Seal drain circuit A: To each valve Function It releases the residual pressure of LS pressure PLS . It makes the speed of the rise in pressure of LS pressure PLS more gentle. In addition, with this discarded throttled flow, it creates a pressure loss in the throttled flow of the spool or shuttle valve, and increases the stability by lowering the effective LS differential pressure. Operation The pressurized oil for LS circuit PLS passes from clearance filter a (formed by the clearance between LS bypass plug (1) and the valve body) through orifice b and flows to seal drain circuit TS .

D31/37EX, PX-21 10-95