Komatsu — SOLENOID VALVE

STRUCTURE AND FUNCTION, MAINTENANCE STANDARD SOLENOID VALVE 1. Nut 4. Connector 7. Spool 2. Plunger 5. Push pin 8. Block 3. Coil 6. Spring Operation When solenoid is de-energized The signal current does not flow from the con- troller, so coil (3) is de-energized. For this reason, spool (7) is pushed fully to the left by spring (6). As a result, port A closes and the flow of pres- surized oil from the pump does not flow to actu- ator (9). At the same time, the oil from actuator (9) flows from port B to port C and then, it is drained.

When solenoid is energized When the signal current flows to the solenoid valve, coil (3) is excited, and propulsion force to the right is generated in plunger (2). For this reason, spool (7) is pushed to the right by push pin (5). As a result, the pressurized oil from the pump flows from port A through port B , and goes to actuator (9). At the same time, port C closes, so the oil is not drained. 10-12 D31/37EX, PX-21