Komatsu — AS VALVE

STRUCTURE AND FUNCTION, MAINTENANCE STANDARD AS VALVE 2. When preventing overrun If the flow of oil from the charge pump becomes greater than the specified oil flow, valve (6) moves to the right, port C is connected with the drain circuit, and the basic pressure circuit of the travel PPC valve becomes the drain pressure. As a result, the output pressure of the travel PPC valve of the piston pump displacement control is also suddenly reduced, so the pump displacement is reduced. When the machine travels down a hill, the motor may act as a pump, so the braking oil pressure of the HST circuit acts as a braking force to pre- vent the machine from running away. Unit: mm No.

Remedy 1 Replace spring if damaged or deformed 2 3 10-34 D31/37EX, PX-21 Check item Criteria Spring Standard size Repair limit Installe Free Installed load length length (N{kg}) d Installed Free load length (N{kg}) 117.6 23.0 18.6 {12} 94.1 — {9.6} Spring 158.8 27.6 17.7 {16.2} 127 — {13.0} Spring 29.4 31.3 23.8 {3.0} 23.5 — {2.4}