Komatsu — HST MOTOR

STRUCTURE AND FUNCTION, MAINTENANCE STANDARD HST MOTOR 3. Operation of piston motor Principle Let us assume that the shaft of a disc is sup- ported to allow the disc to rotate freely. If force F is applied to this disc at an angle, this force F can be divided into force F1 applied at a right angle to the face of the disc and force F2 applied in the direction of the circumference of the disc. Force F1 pushes the disc in the axial direction, and force F2 rotates the disc in a clockwise direction. If force F' is applied to the disc instead of force F, the force can be divided in the same way into forces F'1 and F'2, and force F'2 will rotate the disc in a counterclockwise direction.

Structure Seven pistons (2) are installed with a spherical connection to the disc portion of output shaft (1). Pistons (2) are at a certain angle to drive shaft (1) and are fitted inside cylinder block (3). The angle of cylinder block (3) and pistons (2) is decided by the ON-OFF signal of the control pressure to PCMIN and PCMID of 3rd speed valve (4). The combination is as shown in the table. PCMIN PCMID Operation The oil sent under pressure from the main piston pump enters from the piston motor inlet port. Oil pressure is formed at the rear face of piston (2), and drive shaft (1) is rotated by angle Q of pis- ton (2) and the cylinder block.

10-38 D31/37EX, PX-21 Motor capacity MAX (1st) OFF OFF Motor capacity MID (2nd) OFF ON Motor capacity MIN (3rd) ON OFF