STRUCTURE AND FUNCTION, MAINTENANCE STANDARD STEERING, DIRECTIONAL PPC VALVE 5. When operated to FORWARD (REVERSE) (characteristics of operating effort) When lever (12) is operated to FORWARD (REVERSE), protrusion a of boss (15) contacts pin (16) installed to piston (14) that is being held by spring (13). (Operating effort characteristics graph C ) If lever (12) is operated further, protrusion a of boss (15) pushes up piston (14) with pin (16) installed. (Operating effort characteristics graph A ) The fine control lever is held by the disc brake (11) over the whole range of movement of the lever, so even if the lever is released, it will be held at the desired position.
(Operating effort characteristics graph D ) When the lever is operated to the end of its stroke, pin (16) is pushed into concave portion b of boss (15), so the lever is held at the full stroke position. When returning the lever (12), it pushes pin (16) up at concave portion b . (Operating effort characteristics graph B ) D31/37EX, PX-21 10-51