SERVICE PROCEDURE MAINTENANCE Use city water for the cooling water. If river water, well water or other such water supply must be used, contact your Komatsu distributor. We recommend use of an antifreeze density gauge to control the mixing proportions. Prepare the following: Container to mix the coolant:Min 50 liters (13.21 US gal) capacity 1. Stop the engine and tighten 2 valves (1) of the corrosion resistor. 2. Turn radiator cap (2) slowly to release the pressure, then remove it. 3.
Set a container in position to catch the drained antifreeze mixture, then open drain valve (3) under the left side of the fuel tank and drain plug (4) at the side face of the cylinder block, and drain the coolant. 4. After draining the coolant, close drain valve (3) and drain plug (4) and fill with city water. 5. When the radiator is full, start the engine, and run it at low idling. Keep the engine running at low idling for 10 minutes until the water temperature reaches more than 90°C (194°F). 6. 6. Stop the engine, open drain valve (3) and drain plug (4), drain the water, then tighten them again. 7. After draining the water, clean the cooling system with cleaning agent.
For the cleaning method, see the instructions for the cleaning agent. 8. Replace the corrosion resistor, then open 2 valves (1). For details of the procedure for replacing the corrosion resistor, see “REPLACE CORROSION RESISTOR CARTRIDGE ( 4-51 )“. 9. Add cooling water until it overflows from the water filler. Decide the proportions of antifreeze and water according to the table for the mixing rate of water and anti- freeze. 10.To remove the air in the cooling system, run the engine for 5 minutes at low idling, and for another 5 minutes at high adling. (When doing this, leave the radiator cap off.) 4-22