Komatsu — CHANGE OIL IN HYDRAULIC TANK, REPLACE HYDRAULIC FILTER ELEMENT

MAINTENANCE SERVICE PROCEDURE 8. Remove mounting bolts (6) of filter cover (5) at the top of the tank, then remove the cover. When the cover is removed, the force of spring (7) may make the cover fly off, so keep the cover pushed down when removing the bolts. 9. Remove spring (7) and bypass valve (8), then remove ele- ment (9). 10.Check that there is no foreign material inside the tank, then clean it. 11.Install new element (9), then set bypass valve (8), spring (7), and cover (5) to the tank. If the O-ring of the cover is damaged or deteriorated, replace it. 12.When installing the cover bolts, push down the cover and tighten the bolts evenly.

13.Add engine oil through oil filler port (F) to the specified level, then install cap (F). 14.Check that the hydraulic oil is at the standard level. For details, see “CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL ( 4-39 )“. 15.Run the engine at low idling,and extend and retract the steering, bucket, and lift arm cylinders 4 to 5 times. Be careful not to operate the cylinder to the end of its stroke (stop approx.100 mm (3.9 in) before the end of stroke). NOTICE If the engine is run immediately at high speed or the cylinder is operated to the end of its stroke,the air inside the cylinder will cause damage to the piston packing.

16.Next, operate the steering, bucket, and lift arm cylinders to the end of their stroke 3 to 4 times, then stop the engine and loosen bleed plug (10) to bleed the air from the hydraulic tank. After bleeding the air, tighten plug (10) again. Run the engine at low idling when bleeding the air. 17.Check that the hydraulic oil is at the standard level. For details, see “CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL ( 4-39 )“. 18.Next, increase the engine speed and repeat the procedure in Step 16 to bleed the air. Continue this operation until no more air comes out from plug (10). 19.After completing the air bleed operation, tighten plug (10). Tightening torque:

11.3 ± 1.5 NІm (1.15 ± 0.15 kgfІm, 8.3 ± 1.1 lbft) 20.Check that the hydraulic oil is at the standard level. For details, see “CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL ( 4-39 )“. 21.Check that there is no leakage of oil from the filter cover mount. 4-53