HANDLING LOAD METER ATTACHMENTS, OPTIONS LOAD METER FUNCTIONS 0. Operation of the various functions of the load meter is carried out by using monitor panel mode selector switch 1 or monitor panel mode selector switch 2 on the front switch panel and the load meter cancel switch and load meter sub total switch on the bucket control lever. There are the following two types of measurement methods in the load meter mode. Addition mode (measuring total amount loaded) This method is useful for measuring the production, such as the amount loaded into the dump truck, the amount loaded into the hopper, or the total work for half a day.
The data can be displayed up to a maximum of 9999 tons for each type of work. Remain method (measuring amount remaining) Use this method for work requiring a determined amount (prevention of overloading, distribution of material, etc.) LOAD METER ADDITION MODE For details of the method of switching to the addition mode, see “SETTING ADDITION MODE ( 6-7 )“. “TOTAL LOADED“ lights up on load meter display (1). The bucket load is displayed on load meter display (2), and the total load is displayed on display (3).
6-4 (1) Addition mode display (4) Bucket load display (2) Remain mode display (5) Material type display (3) TOTAL LOADED display (addition mode) or REMAINING TARGET display (remain mode) (6) Speed display or engine speed display