ATTACHMENTS, OPTIONS HANDLING LOAD METER The total load data for each of A to E and for all data is dis- played on the load meter display. Check the material selection display on load meter display (1). In the example on the right, all of A to E for all data selected light up. On display (2) the total load data for all data or individual total load data for A to E is displayed. On display (3) the individual number of loads for A to E is dis- played. The total value can be cleared as follows. 1) Press the (>) or ( switch 2, and select the individual items to be cleared from A to E or select the all lighted-up display. 2) Press the ( ‘ ) of monitor panel selector switch 1 to dis- play “RESET“.
3) “YES NO" is displayed, and the cursor is at the NO position, so press the ( switch 2 to move the cursor to the "Y" of YES. 4) Press the ( „ ) of monitor panel mode selector switch 1. The selected individual item from A to E or all the data is cleared. If the monitor accepts the clear command, the buzzer gives short sounds and the display returns to the normal service meter and time display. 6-13