Komatsu — CARRYING OUT CALIBRATION (ADJUSTING 0 POINT) WHEN LOADED

ATTACHMENTS, OPTIONS HANDLING LOAD METER 13.Input the load on the target load input screen. The data for the previously calculated load is displayed on the input screen. The cursor is at the 100 ton position. The following explanation explains the procedure when inputting 7.5 tons as the target when the previous load (the load set in Step 7) is 7.1 tons. 14.“0“ is displayed at the 100 ton position, so leave it at “0“ and press the ( ‘ ) of monitor panel selector switch 1 twice. “00“ is selected and the cursor moves to the 1 ton position. 15.“7“ is already displayed at the 1 ton position, so press the ( ‘ ) of monitor panel mode selector switch 1.

“7“ is selected and the cursor moves to the 0.1 ton position. 16.“1“ is displayed at the 0.1 ton position, so press the ( ‘ ) of monitor panel mode selector switch 1. “.5“ is selected and 7.5 tons is set as the target load. 17.Press the ( ‘ ) of monitor panel mode selector switch 1. If the monitor accepts the setting, the buzzer gives short sounds, and the setting of the loaded calibration is com- pleted. The screen returns to the normal service meter and time display. 6-19