Komatsu — OPERATION

CENTRAL LUBRICATION ATTACHMENTS, OPTIONS CENTRAL LUBRICATION 0. OPERATION 0. Turn the starting switch ON. OPERATION AS DESIRED If auto-greasing switch (1) on the right switch panel or the start button of the lubrication controller inside the box under the step on the left side of the machine are pressed, one cycle of greas- ing will be carried out regardless of the hours of operation. The time count for the greasing interval will be canceled, and when the electric pump automatically stops, the count will start again. PILOT LAMP DISPLAY ON MACHINE MONITOR The display of pilot lamp (2) on the machine monitor lights up or flashes according to the following conditions. Lighted up:

Normal operation 1 flash per sec: Grease cartridge empty 2 flashes per sec: Defective decompression The settings when shipping from the factory are as follows. Greasing interval: 1 hour Greasing time: 12 minutes 6-42