. OPERATION TROUBLESHOOTING installed on the REMARK 3 - 115 IF ACCELERATOR PEDAL HAS FA In addition to the potentiometer accelerator pedal assembly in ord er to detect whethe r the a ccelerator pedal is depress ed or no If the pedal depression depth is no t detected correctly due t o a failure o f the accelerato r pedal o r incorrect electric wiring, the e ngine controller or PM C (if equipped) controls the engine speed re sponding t o the sig nal from this check switch. The engine runs at 1400 rp m when the accelerator p edal is depresse d, while th e engin e runs a t low idling when the p edal is released.
The e ngine speed varies depending on the load After movin g the machine to a safe place by operating the a ccelerator p edal, check the service code, t hen c ontact your Komat su distributor for repair There are tw o methods when opera ting the accelerator pedal :
either r elease th e pedal an d set to t he OFF (low idling) position, or depress the pedal fully If the accel erator pedal is held at a n intermediate position, t he system may n ot be able to judg e if the accelerator pedal is bei If the engin e controller or PMC (if equipped) can not r eceive the signal of the accelera tor pedal depth, the central warning lam p flashes and simultan eously the alarm b uzzer sounds and user code 02 a ppears.