Kaiyi PC95R-2 — HEATING FAN UNIT

REMOVAL AND INSTALLATION HEATING FAN UNIT REMOVAL OF HEATING FAN UNIT Lower the work equipment until it is resting on the ground and switch off the engine. Disconnect the cable from accumulator negative termi- nal (–). 2 Drain the coolant liquid to a level below that of the con- necting pipes (2) and (3) between the engine and the heating fan. 1 3 Cooling liquid: approx. 5 1 - Disconnect clamp (1) and pipes (2) and (3) from the en- gine and lower the terminals so as to thoroughly drain the liquid from the heating radiator. RKPB1754 Cooling liquid: approx. 1.5 2 - Move the back of the operator's seat completely forward and remove the panel (5) fixing screws (4).

7 3 - Raise the panel (5), disconnect the heating hose (6) from the diffuser (7). 4 6 5 5 RKPB 6221 4 - Remove the knob (8) and (9), loosen the screw (10) and remove the hood (11). 9 10 8 11 RKPB 6241 5 - Remove the clamps (12) and the sleeve (13). 13 12 12 RKPB 6591 30-30 PC95R-2