Kaiyi PC95R-2 — CONTROL VALVE

STRUCTURE AND FUNCTION CONTROL VALVE 2. When lowering the boom, if the head pressure B of the cylinder (1) is greater than the bottom pressure A , and the op- eration is in the load process, the check valve (3) closes to shut off the circuit between the head and the bottom sides. 1 B A 4 2 3 T a P LS P P RKP03090 OPERATION During a load process such as lowering the boom, etc., the pressure B at the head side of the boom cylinder (1) becomes higher than the pressure A at the bottom side. At this time, the check valve (3) is closed by the pressure B at the head side and the spring (4), and the passage between the head circuit and the bot- tom circuit is shut off. 10-71 PC95R-2