Yanmar — 6.1.2 Fuel injection pump service data and adjustment

6. Fuel injection equipment Fuel adjustment for 3YM20 1) Loosen the nut of the FO limiter, and screw the adjusting bolt to the bottom. Tighten the nut. 2) Adjust the rack position to R0 (15mm) with the FO limiter, and measure the injection volume (A) at the rated speed. 3) When the measured injection volume (A) is out of the standard, readjust the injection volume by screwing the FO limiter. 4) Pull the control lever to high idle side at full rack position. 5) Adjust the position of the high idle set bolt at high idle speed as to get the specified injection volume (B). 6) Loosen the nut of the FO limiter, and loosen the adjusting bolt at 180 ° . Fix the nut.

7) Screw the angleichi at the torque-rise speed to get the specified injection volume (C). 8) Confirm the injection volume (D) at the specified speed at starting. 9) Push the control lever to low idle side. 10) Adjust the position of the low idle set bolt at low idle speed as to get the specified injection volume (E). (D) Rs 19 0.5 (C) Rack position (mm) (A) R 0 15 (E) (B) Pump seed N (min -1 ) 138R1 1. Loosen nut 3. Tighten nut 2. Screw angleich. Adjust injection volume to (C) by screwing. (Adjustment procedure for 7)) 001561-00E t t t t ume to (C) by screwing. procedure for 7)) 001561-00E High idle set bolt Low idle set bolt (Adjustment procedure for 5) and 10))