Yanmar — 9.1 Cooling water system

9. Cooling water system 9. Cooling water system 9.1 Cooling water system The cooling water system is of the indirect seawater cooled, fresh water circulation type. The cylinders, cylinder heads and exhaust manifold are cooled with fresh water, and fresh water cooler (heat exchanger) use seawater. Seawater pumped in from the sea by the seawater pump goes to the heat exchanger, where it cools the fresh water. Then it is sent to the mixing elbow and is discharged from the ship with the exhaust gas. Fresh water is pumped by the fresh water pump to the cylinder jacket to cool the cylinders and the cylinder head.

The fresh water pump body also serves as a discharge passageway (line) at the cylinder head outlet and is fitted with a thermostat. The thermostat is closed when the fresh water pump temperature is low, immediately after the engine is started and during low load operation, etc. Then the fresh water flows to the fresh water pump inlet, and is circulated inside the engine without passing through the heat exchanger. When the temperature of the fresh water rises, the thermostat opens, fresh water flows to the heat exchanger, and it is then cooled by the seawater in the tubes as it flows through the cooling pine. The temperature of it flows through the cooling pine.

The temperature of the fresh water is thus kept within a constant range by the thermostat. Seawater circuit Fresh water circuit Heat exchanger Coolant recovery tank Mixing elbow Thermostat Cylinder head P Cylinder block Fresh water pump P Seawater pump Sea cock 157R1