Komatsu — Cleaning

Maintenance - Section 40 OM4039 Page 40-16 Lubrication and Service HYDRAULIC FILTERS Filter Replacement 1. Lower the dump body and shut down the engine. Release hydraulic tank filler cap slowly to remove any internal pressure. 2. Turn the oil filler caps (3 & 8, Figure 40-3) slowly counterclockwise to release internal tank pressure. 3. Remove bolts (2) on filter covers (1). 4. Remove the elements (2, Figure 40-4) from housing. 5. Thoroughly clean filter housings, covers (4) and bypass valve (3) components. FIGURE 40-4. HYDRAULIC TANK FILTERS 1. Hydraulic Tank 2. Filter Element 3. Bypass Valve 4. Cover 6. Install new elements. Install bypass valves and covers.

Tighten bolts (2, Figure 40-3) to stan- dard torque. 7. Check oil level; oil must be visible in sight glass. HYDRAULIC TANK BREATHER Cleaning 1. Shut down the engine and open hydraulic tank filler caps slowly to relieve any internal pres- sure. 2. Clean dirt accumulation from area of breather (9, Figure 40-3). 3. Remove the breather from the tank. 4. Remove snap ring (1, Figure 40-5), cover (2) and filter element (3). 5. Clean breather element in solvent and blow dry. Clean remaining parts in solvent and dry thor- oughly. Replace element, if element appears damaged or doesn't clean up thoroughly. 6. Install element, cover and snap ring. 7. Install breather element on hydraulic tank.

FIGURE 40-5. HYDRAULIC TANK BREATHER 1. Snap Ring 2. Cover 3. Element