Komatsu — Clearing The Failure Code

Operation - Section 32 OM3210 Page 32-16 Operator Cab and Controls Clearing The Failure Code Turn the truck key switch to ON (without starting the engine) and disconnect connectors CR1 and CR2 protruding from the wire harness routed to the ASR/ ARSC controller connectors. NOTE: When using the ASR or ARSC for the first time, always clear the failure codes. After clearing the codes, connect connectors CR1 and CR2. When this is done, “– –” is displayed on the controller LED. When the “– –” changes from flashing and remains lit (3 seconds), the failure code has been cleared.

FAULT CODE TABLE FAILURE CODE APPLICABLE SYSTEM DETAILS WARNING TYPE ASR ARSC 8.7 X X Failure in pressure control valve system (right) or failure in pressure switch 1 system 1 8.9 X X Short circuit to ground in pressure cracking valve 1 9.0 X X Open, short circuit in pressure cracking valve 1 9.1 X X Failure in pressure cracking valve (remains open) or failure in pressure switch 2 sys- tem 1 9.2 X X Failure in pressure cracking valve (does not open) or failure in pressure switch 2 sys- tem 1 9.3 X Open circuit, short circuit in system switch (See Note below) 1 9.4 X Short to ground in system switch (See Note below) 1 9.5 X Open, short circuit to ground in travel speed set switch system 1 NOTE:

If the failure code is “9.3” or “9.4”, it indicates a failure in the system switch. Even though the ARSC system switch is turned OFF, the central warning lamp and ASR/ARSC caution lamp will flash and the buzzer will sound.