Terex TR60 — Sm1564

Transmission - CEC Plus II Shift System Section 120-0070 ECU Electromagnetic Shield - Ground SM - 426 Refer to Fig. 15. Must be grounded to protect ECU. GROUND TO PASSENGER SEAT BOX Fig. 15 - ECU Electromagnetic Shield - Ground Mode Selection Switch Refer to Fig. 16. 1. With mode selection switch in Economy (open) position, ECU will control transmission as per the Economy mode shift schedule. 2. With mode selection switch in Power (closed) position, Lines 313 and 315 are connected to Line 309 and the ECU will then control the transmission as per the Power mode shift schedule. MODE SELECTION SWITCH SECONDARY MODE HARNESS - J3 SM - 429 Fig.

16 - Mode Selection Switch Manual Mode Switch connected to Line 309 and ECU will change operation of transmission from automatic to manual. Refer to Fig. 17. 1. With ignition keyswitch at position '2' and manual mode switch 'On' (closed) indicator light on console will illuminate. Note: Both switches must be closed and transmission in neutral to obtain manual mode. 2. When mode selection switch is in the Power (closed) position and manual mode switch is in the 'On' (closed) position, Lines 311, 313 and 315 are all Note: CEC wires B (309) and 311 are 12 volt and W/B wires at manual mode switch are 24 V. Improper connection of wires could lead to CEC damage. IND.

LIGHT SM - 430 MANUAL MODE SWITCH MODE SELECTION SWITCH SECONDARY MODE HARNESS - J3 24V SUPPLY FROM IGN. SWITCH Fig. 17 - Manual Mode Switch 12 SM 1575 Rev 2 11-00