SEN01351-00 10 Structure, function and maintenance standard Operation 1) When pump controller is normal (1) When the load on the actuator is small and pump discharge pressures (PP1) and (PP2) are low Action of PC-EPC valve solenoid (1) q Command current (X) is being sent to PC-EPC valve solenoid (1) from the pump controller. a Other pump's pressure denotes the pressure of the pump situated on the opposite side. For the front pump pressure, the other pump's pressure is that of the rear pump. And for the rear pump pressure, the other pump's pressure is that of the front pump.
q This command current acts on PC-EPC valve to output the signal pressure in order to modify the force pushing piston (2). q Spool (3) stops at a position where the com- bined spool-pushing force is balanced by the setting force of springs (4) and (6) as well as the pump pressures (PP1) (self-pressure) and (PP2) (another pump's pressure). q The pressure [port (C) pressure] output from PC valve is changed depending on the above position. q The size of command current (X) is determined by the nature of the operation (lever opera- tion), the selected working mode, and the set value and actual value of the engine speed. 16 BR380JG-1E0