10 Structure, function and maintenance standard SEN01351-00 2) When signal current is very small (coil is energized) 3) When signal current is maximum (coil is energized) q When a very small signal current flows to coil (2), coil (2) is energized, and a propulsion force is generated on the right side of plunger (7). q As the signal current flows to coil (2), coil (2) is energized. q When this happens, the signal current is at its maximum, so the propulsion force of plunger (7) is also at its maximum. q Rod (6) pushe spool (5) to the right, and pres- surized oil flows from port (P) to port (C).

q Pressures on port (C) increases and the force to act on spool (5) surface and the spring load on spring (4) become larger than the propul- sion force of plunger (7). q Spool (5) is pushed toward right side by rod (6). q The maximum volume of pressurized oil is conducted from port (P) to port (C), increasing the circuit pressure across EPC valve and LS (PC) valve to the maximum level. q Spool (5) is pushed to the left, and port (P) is shut off from port (C). q Port (C) and port (T) are connected. q Since port (T) is closed, pressurized oil does not flow to the tank.

q Spool (5) moves up and down so that the pro- pulsion force of plunger (7) may be balanced with pressure of port (C) + spring load of spring (4). q The circuit pressure between the EPC valve and the LS (PC) valve is controlled in propor- tion to the size of the signal current. BR380JG-1E0 23