SEN01352-00 10 Structure, function and maintenance standard 3. System diagram a This shows actuator (6A) at stroke end relief in the merge mode (on the BR380JG-1E0, this is always in the divide mode). 1A. Main pump 5A. Control valve 9A. Tank passage 1B. Main pump 5B. Control valve 9B. Tank passage 2A. Main relief valve 6A. Actuator 10A. Valve 2B. Main relief valve 6B. Actuator 10B. Valve 3A. Unload valve 7A. Pump passage 11A. Spring 3B. Unload valve 7B. Pump passage 11B. Spring 4. Merge-divider valve 8A. LS circuit 12. LS bypass valve 8B. LS circuit 18 BR380JG-1E0