Kaiyi BR380JG-1E0 — FUNCTIONS AND OPERATION BY VALVE

10 Structure, function and maintenance standard SEN01352-00 q During operation (a work within a scope of dis- charge by a minimum swash plate angle), the discharge pressure for the portion of minimum pump swash plate angle is set to LS pressure + P1 pressure. 2. Operation of relief valve (Cut-off Control Actuated) Function q LS control differential pressure ( d PLS) of dis- charge for the portion of minimum swash plate angle will be equal to P1 pressure. q When cut-off control is being carried out on the pump by the PC valve, the pump swash plate angle is at the minimum.

q The relief valve acts to relieve the oil flow when the pump is at the minimum swash plate angle in order to maintain the balance. Operation q When the cylinder reaches the stroke end, the main relief valve opens. q The pump delivery (Q) is relieved to the tank. (See the system diagram) q When pump discharge pressure (PP) comes close to the relief pressure, the engine throttle and pump controller sends a signal to the sole- noid of the PC valve. q Carries out the cut-off function to make pump delivery (Q) the minimum.

q The pump discharge pressure (PP) and LS pressure (PLS) become approximately the same as each has not flow at the upstream and downstream of the spool, and LS differential pressure ( d PLS) becomes 0 MPa{0 kg/cm 2 }. q As LS differential pressure ( d PLS) is lower than the LS set pressure of LS valve, LS valve is actuated to maximize the pump swash plate angle. q Mechanically, operation of PC valve have the prevalence to that of LS valve. q The pump is held at a minimum swash plate angle by the cut-off function of PC valve. BR380JG-1E0 21