Kaiyi BR380JG-1E0 — FUNCTIONS AND OPERATION BY VALVE

SEN01352-00 10 Structure, function and maintenance standard 3. Pressure compensation valve area ratio Function q The state of division changes according to the area ratio of pressure compensation portion (A1) and (A2). Area ratio = (A2)/(A1) q If area ratio = 1 : The spool meter-in downstream pressure will be equal to the maximum load pressure, and the pressure will be divided according to the opening area ratio. q If area ratio = 1 or over : The spool meter-in downstream pressure will be greater than the maximum load pressure, and the pressure will be divided smaller than the opening area ratio. q If area ratio = 1 or under :

The spool meter-in downstream pressure will be smaller than the maximum load pressure, and the pressure will be divided greater than the opening area ratio. 26 BR380JG-1E0