10 Structure, function and maintenance standard SEN01352-00 Merge-divider valve 1 1. When flows from the pumps merge [if pilot pressure (PS) is OFF] a On the BR380JG-1E0, pilot pressure (PS) is always ON and the flow is always divided. 1. Main spool 2. Spring 3. LS spool 4. Spring 5. LS circuit (if equipped 4 side) 6. LS circuit (conveyor PAISE/LOWER side) 7. LS circuit (conveyor PAISE/LOWER side) 8. LS circuit (if equipped 4 side) Function q Since pilot pressure (PS) is OFF for LS spool (3), it is pressed to the left by spring (4), and ports (A) – (D) and ports (B) – (C) are intercon- nected.
q Merges pressurized oil (P1) and (P2) dis- charged from the two pumps or divides (to respective control valve group). q Merges and divides LS circuit pressure. q Forwards LS pressure led from respective con- trol valve spools to LS circuits (5), (6), (7) and (8) to all the pressure compensation valves. q Pilot pressure (PS) is OFF, so main spool (1) is pressed to the left by spring (2) and ports (E) and (F) are interconnected. Operation q Merges pressurized oil (P1) and (P2) dis- charged from the two pumps at ports (E) and (F) and sends to necessary control valve. BR380JG-1E0 29