Kaiyi BR380JG-1E0 — SOLENOID VALVE

10 Structure, function and maintenance standard SEN01353-00 1. Connector 5. Spool 2. Movable core 6. Block 3. Coil 7. Spring 4. Cage Operation When solenoid is de-energized q When the signal current does not flow from the controller, solenoid (3) is de-energized. For this reason, spool (5) is pushed fully to the left by spring (6). As a result, the circuit between ports (P) and (A) closes and the pressurized oil from the control pump does not flow to the actuator. At the same time, the pressurized oil from the actuator flows from port (A) to port (T), and is then drained to the tank.

When solenoid is energized q When the signal current flows from the control- ler to solenoid (3), solenoid (3) is energized. For this reason, spool (5) is pushed to the right in the direction of the arrow. As a result, the pressurized oil from the control pump flows from port (P) through the inside of spool (5) to port (A), and then flows to the actu- ator. At the same time, port (T) is closed, and this stops the oil from flowing to the tank. BR380JG-1E0 27