Kaiyi BR380JG-1E0 — ELECTRONIC CONTROL SYSTEM

10 Structure, function and maintenance standard SEN01355-00 Function q Matching point: 107.0 kW/1,800 rpm {143.5 HP/1,800 rpm} q The work equipment and pump controller con- trols the pump so that it can absorb all the torque at the output points of the engine depending on the pump absorption torque specified beforehand, rotation set by the fuel control dial, and actual engine speed. q Engine speed is always controlled so that it is kept around the matching point specified beforehand. q If the pump load increases and the pressure rises, engine speed (N) lowers.

If it happens, the engine speed is increased to around the matching point, allowing the pump controller to decrease pump delivery (Q). On the contrary, the pump load decreases and the pressure lowers, the pump controller continues to increase pump delivery until the engine speed reaches around the matching point. BR380JG-1E0 19