Kaiyi BR380JG-1E0 — ELECTRONIC CONTROL SYSTEM

10 Structure, function and maintenance standard SEN01355-00 Travel speed change function 1. Manual change with travel speed selector switch If the travel speed selector switch is changed over Lo, Mi and Hi, the work equipment and pump controller controls the pump capacity at each gear speed as shown below to change the travel speed. 2. Automatic change by selecting conveyor posi- tion and radio control selection mode 1) The conveyor position is judged to be upper, middle or lower position by the con- veyor upper position sensor and conveyor middle position sensor. 2) The position of the radio control selector switch is judged. 3) The position of the mode selector switch is judged.

4) The drive signals for the travel lock EPC valve and LS-EPC valve are output according to 1) – 3) and position of the travel speed switch to change the travel interlock and travel speed automatically. Ч: Machine cannot travel. BR380JG-1E0 25 Travel speed selector switch Lo Mi Hi Pump capacity (%) 27 77 100 Travel motor capacity Max. Max. Max.

Travel speed (km/h) 0.8 2.3 3.0 Mode Control method Radio control selection Travel speed selection Position of conveyor Upper Middle Lower Travel Lever Panel Hi High speed Middle speed × Mi Middle speed Middle speed × Lo Low speed Low speed × Radio control — × × × Radio control Panel — × × × Radio control Hi High speed Middle speed × Mi Middle speed Middle speed × Lo Low speed Low speed × Work Lever Panel — × × × Radio control — × × × Radio control Panel — × × × Radio control Hi × Middle speed × Mi × Middle speed × Lo × Low speed ×