10 Structure, function and maintenance standard SEN01355-00 q Crusher clearance adjustment switch This switch is used to adjust the crusher clear- ance manually. This switch is effective when the manual adjustment mode (M mode) is selected in the inspection mode. q Crusher manual rotation switch This switch is used to rotate the crusher manu- ally. This switch is effective when the crusher stops in the work/inspection mode. q Conveyor manual rotation switch This switch is used to rotate the conveyor man- ually. This switch is effective in the inspection mode. q Crusher speed setting screen selector switch This switch is used to set the crusher speed.
If this switch is depressed, the speed setting screen appears and you can set the crusher speed. q Operation switch This switch is used to use various setting func- tions. (For details, see the section of each function.) q Buzzer cancel switch When the machine detects abnormality and the buzzer of the multi monitor sounds, stop the buzzer with this switch. The buzzer sounds when any of the following is detected.
q Abnormal coolant level q Abnormal engine oil pressure q Overheating of engine coolant q Abnormality in fuel control dial potentiom- eter q Disconnection or short circuit in pump PC- EPC valve q Disconnection or short circuit in governor motor phase A or B q Maintenance switch This switch is used to check the maintenance items. a For the maintenance items, see Mainte- nance function. q Display brightness and contrast adjust- ment switch This switch is used to adjust the brightness and contrast of the display. BR380JG-1E0 41