Kaiyi BR380JG-1E0 — MACHINE MONITOR SYSTEM

10 Structure, function and maintenance standard SEN01355-00 Crusher load setting function q This function is used to set the crusher load. The material is crushed properly, regardless of its type, by adjusting the crusher pressure switch in proportion to the load level. q This function is used while the ordinary screen (travel mode, work mode, or inspection mode) is displayed. How to use 1) Depress crusher load set switch (1) of the monitor to display the adjustment screen. 2) Depress the operation switch (2) to select the crusher load. Operation switch Operation Bar graph extends to right. Bar graph retract to left. 3) After selecting the level, depress input check switch (3).

The selected crusher load level is settled and the ordinary screen appears. At the same time, the crusher load changes. a The crusher load does not change until the input check switch is depressed. If return switch (4) is depressed to return to the ordinary screen without depressing the input check switch, the original setting is maintained. BR380JG-1E0 47