Kaiyi BR380JG-1E0 — BLEEDING AIR FROM EACH PART

30 Testing and adjusting SEN02303-00 a If the oil does not flow out of the air bleeder: 3) Leave bleeder (1) loosened, disconnect drain hose (2), and remove elbow (3). 4) Add oil through the elbow mounting hole until it flows out of the bleeder (1). 5) Install elbow (3) and connect drain hose (2). 2) If the oil does not flow out, stop the engine, disconnect the drain hose, and fill the motor case with oil. 3) After bleeding air, tighten the drain hose. 4) Run the engine at low idle to rotate the motor slowly. 4. Bleeding air from crusher motor 1) Run the engine at low idle, loosen drain hose (1), and check that oil flows out of the drain port. 6) Tighten air bleeder (1). 3 Bleeder:

7.8 – 9.8 Nm {0.8 – 1.0 kgm} 9JH05861 2. Starting engine When running the engine after performing step 1, keep its speed at low idle for 10 minutes. a If the engine coolant temperature is low and the automatic warm-up operation is started, stop the engine temporarily and reset the automatic warm-up operation with the fuel control dial (Set the starting switch in the ON position and hold the fuel control dial in the MAX position for 3 sec- onds, and the automatic warm-up opera- tion is reset). 2) If the oil does not flow out, stop the engine, disconnect the drain hose, and fill the motor case with oil. 3) After bleeding air, tighten the drain hose.

4) Run the engine at low idle to rotate the motor slowly. 5. Bleeding air from travel motor 1) Run the engine at low idle. 2) Loosen air bleeder (2) and check that oil oozes out through the air bleeder. 3) After the oil oozes out, tighten air bleeder (2). 3 Air bleeder: 27.5 – 35.3 Nm {2.8 – 3.6 kgm} 3. Bleeding air from grizzly feeder motor 1) Run the engine at low idle, loosen drain hose (1), and check that oil flows out of the drain port. BR380JG-1E0 43